Choose your region and language

Global
Argentina
Australia
Austria
Bahrain
Brazil
Bulgaria
Canada
Chile
China
Colombia
Czech Republik
Denmark
Egypt and North Africa
Finland
France
Germany
Greece
Hungary
India
Indonesia
Iraq
Ireland
Italy
Japan
Jordan
Kuwait
Malaysia
Mexico
New Zealand
Norway
Oman
Pakistan
Panama
Peru
Philippines
Poland
Portugal
Qatar
Saudi Arabia
Singapore
Slovakia
South Africa
South Korea
Spain
Sweden
Switzerland
Taiwan, China
Thailand
Türkiye
Ukraine
United Arab Emirates
United Kingdom
United States
Vietnam
English
Spanish
English
German
English
Portuguese
English
English
French
Spanish
Chinese
Spanish
English
English
English
English
French
German
English
English
English
English
English
Italian
Japanese
English
English
English
Spanish
English
English
English
Spanish
Spanish
English
Polish
English
English
English
English
English
English
English
Spanish
Swedish
German
French
Italian
English
English
English
English
English
English
English
English
Go

Menu

Generator circuit-breaker HEC 10 up to 210 kA

High-performance system solution for demanding power plant applications

HEC 10 GCB is a compact design capable of carrying normal currents up to 29,000 A as well as interrupting short-circuit currents up to 210 kA to protect the most critical generator applications up to 1,500 MW. Based on the well-proven HEC technology with over two decades of successful field experience, it is an enhancement of type HEC 7/8/9 with the following features:
 

  • Fully type-tested exceeding the mandatory requirements of the latest GCB standard IEC/IEEE 62271-37-013
  • Equipped with an enhanced passive cooling system design based on the most advanced passive heat pipe technology, patented by Hitachi Energy 
  • Features HMB-8 from the most reliable* spring operating mechanism family to provide safe performance throughout the entire lifespan of the GCB
  • Developed to protect the most demanding generator applications, having a rated generator-source short-circuit breaking current of 160 kA according to G2 class** 
  • Fully assembled and factory tested, brings substantial savings in time and cost for installation and commissioning  

Applications

  • New installations, replacement and retrofit of power plants up to 1,500 MW
  • Demanding generator applications according to G2** class

Why Hitachi Energy?
 

  • Third generation of HEC technology encompassing almost two decades of Hitachi Energy successful field experience
  • Fully type-tested exceeding the mandatory requirements of the latest GCB standard IEC/IEEE 62271-37-013

*  Most reliable spring operating mechanism as per paper A3-206 presented at CIGRE 2012

** For GCB with a rated generator-source short-circuit breaking current characterized at contact separation by a degree of asymmetry of 130 percent with the assigned a.c.component (alternating current) of the rated generator-source short-circuit breaking current.

Available options:
Product image for: Generator circuit-breaker HEC 10 up to 210 kA

Brief performance data

Type HEC 10-170L HEC 10-170XL HEC 10-210L HEC 10-210XL
Rated maximum voltage [kV] 31.5 31.5 33 33
Rated frequency [Hz] 50 / 60 50 / 60 50 / 60 50 / 60
Rated power frequency withstand voltage [kV]
(circuit-breaker / line disconnector)
80 / 90 80 / 90 80 / 90 80 / 90
Rated lightning impulse withstand voltage [kV]
(circuit-breaker / line disconnector)
150 / 165 150 / 165 150 / 165 150 / 165
Rated normal current [A] up to 20,000 up to 29,000 up to 20,000 up to 29,000
Rated short-circuit breaking current [kA] 170 170 210 210

Something caught your eye?